Electrical (fan heater), Vapor and housing high limits / solenoid conduits, Supply line solenoid junction box – Grain Systems PNEG-1376 User Manual

Page 73: High fire solenoid valve. low fire solenoid valve

Advertising
background image

- 73 -

2300 Series Parts Manual

Electrical (Fan Heater)

Vapor and Housing High Limits / Solenoid Conduits

Supply line solenoid junction box.

8

1

7

1

8

1

8

9

8

1

9

10

1

ITEM No.

DESCRIPTION

PART No.

1

SEALTITE PVC 3/8"

FH-7038

2

SEAL 3/8 STRAIGHT PVC W/NUT

FH-7049

3

COUPLER 1/2" SCH 40 BLK

D67-0005

4

SWITCH SCREW-IN VAPOR HI-LIMIT

HH-7013

5

HOUSING HI LIMIT PLATE

D01-1473

6

HI-LIMIT 200 DEGREE MAN RESET

THH-4020

7

UNILET TYPE LRL CONDUITBX1/2"

THH-4064

NEOPRENE GASKET, CONDUIT BODY

TFC-0076

COVER ALUMINUM, CONDUIT BODY

TFC-0075

8

ELBOW 3/8" 90 DEGREE PVC W/NUT

FH-7050

9

TEE CONLET CONDUIT BODY 1/2

TFC-0073

NEOPRENE GASKET, CONDUIT BODY

TFC-0076

COVER ALUMINUM, CONDUIT BODY

TFC-0075

10

CONNECTOR PVC 3/8" 45' W/NUT

F-6913

High fire solenoid valve.

Low fire solenoid valve.

NOTE: Not shown are the 1/2” close nipples (part no. THH-4032) that
connect the conduit junction boxes to the solenoid valves.