Grain Systems Bin Accessories PNEG-1867 User Manual
Page 7
Advertising
1. CFL Series Outside Universal Stiffened Anchor Bolt Charts
PNEG-1867 Concrete Foundation Recommendations for GSI CFL Grain Bins
7
CFL Series Outside Stiffened Tanks 2 Stiffeners per
Sidewall Sheet 4" Commercial Anchor Bolt Placement Charts
NOTE: These tables are for 2 post CFL series outside stiffened bins only.
Nominal
36 Anchors
Diameter
= 54' 2 Post
Bolt Radius
= 27' - 2-1/2"
Anchor Chord
4' - 8-15/16"
9' - 5-7/16"
14' - 1-1/16"
18' - 7-3/8"
23' - 0-1/16"
27' - 2-9/16"
31' - 2-5/8"
34' - 11-13/16"
38' - 5-13/16"
Nominal
40 Anchors
Diameter
= 60' 2 Post
Bolt Radius
= 30' - 2-3/8"
Anchor Chord
4' - 8-7/8"
9' - 5-3/8"
14' - 1-3/16"
18'-8"
23' - 1-3/8"
27' - 5-1/16"
31' - 6-11/16"
35'-6"
39' - 2-11/16"
42' - 8-1/2"
Advertising