Heater operation – Grain Systems PNEG-816 User Manual

Page 15

Advertising
background image

15

Deluxe Vane Axial Heater

HEATER OPERATION

Standard Heater

Operation

1. Thermostat must be wired into heater control

box for heater to operate.

2. Open all manual shutoff valves to heater unit.

3. Start fan. This will supply power to heater.

4. Turn thermostat dial to its highest setting.

5. Turn toggle switch on.

6. Heater should now be lit. If not check to see

that all gas is on.

7. Watch thermometer on plenum and when it

reaches desired temperature turn thermostat
back slowly until heater cycles off.

8. Gas pressure should be adjusted so burner is

on 75% of the time.

9. Watch plenum temperature as burner goes

through a few cycles, to be sure that it is operat-
ing properly.

Hi-Lo Heater

Operation

1. Hi-limit and cycling thermostat must be wired

into heater control box for heater to operate.

2. Open all manual shutoff valves to heater unit.

3. Start fan. This will supply power to heater.

4. Turn thermostat dial to its highest setting.

5. Turn toggle switch on. Both red lights should

light up indicating power to the control circuit.

6. Heater should now be lit. If not check to see
that

all gas is on.

7. Open low-fire ball valve all the way.

8. Turn thermostat dial back slowly until heater

cycles to low flame.

9. Adjust ball valve so that low-flame pressure is

at desired setting.

10. Turn thermostat dial to desired setting and wait

for bin plenum to come up to temperature.

Heater

should cycle to low flame after a few

minutes.

If heater does not cycle to

low flame increase

hi-flame gas pres-

sure.

11. Low-flame should be adjusted so that tempera-

ture drops slowly until burner goes back to high
flame.

12. Watch as burner goes through a few cycles, to

be sure that it is operating properly.back to high
flame.

Advertising