9. 20 Gauge Floor Support Requirements

20 Gauge Grandstand Chart - 2.66" Corrugation

Narrow/2.66" Corrugation - 20 Gauge Grandstand Floor Support Chart

*For Aeration Systems recessed in the concrete, add one (1) ring for proper spacing.

When using FL-3102-3 or FL-3102-6 (3", 6") Grandstands, increase the listed quantities by 33%
(Standard Quantity x 1.33).

Quantities of Grandstands are minimum required for installation - Due to varying conditions and
construction techniques at floor and wall penetrations, additional supports may need to be
ordered.

How to read the chart: For example, a 12' diameter bin with 7 rings would have spacing of 54/27
(the top numbers). Meaning A=54" and B=27". The number of supports needed would be 62,
(the bottom number).

Full Floor Supports Required for Plank Type Flooring 2.66" Corrugation

(* Based upon 13.5" or taller floor heights)

Dia.

12

15

18

21

24

27

30

33

36

39

42

45

48

54

60

72

75

78

90

105

Rings

3

57/27

62

4

54/27

62

58/29

80

54/27

120

5

54/27

62

58/29

80

54/27

120

52/26

160

56/28

205

54/27

249

54/27

304

50/25

390

50/25

470

50/25

576

6

54/27

62

54/27

88

54/27

120

52/26

160

52/26

215

48/24

275

50/25

333

50/25

390

48/24

487

48/24

586

46/23

695

46/23

806

46/23

909

44/22

1196

44/22

1430

7

54/27

62

52/26

96

48/24

138

50/25

168

48/24

225

48/24

275

48/24

347

46/23

425

44/22

523

46/23

606

44/22

735

44/22

836

44/22

933

42/21

1236

42/21

1477

8

48/24

70

48/24

100

48/24

144

46/23

182

46/23

230

46/23

300

44/22

363

44/22

435

44/22

523

44/22

624

42/21

750

42/21

866

42/21

977

40/20

1296

40/20

1544

9

48/24

70

48/24

100

42/21

144

42/21

190

42/21

243

44/22

303

42/21

387

42/21

465

40/20

565

42/21

656

40/20

790

40/20

906

40/20

1019

38/19

1346

36/18

1697

10

42/21

75

42/21

110

42/21

144

42/21

190

42/21

250

42/21

309

40/20

397

40/20

479

38/19

597

38/19

716

38/19

820

36/18

986

36/18

1109

34/17

1486

34/17

1779

18 Gauge COR-LOK or CUT-LOK

if Dia. and number of rings are in

middle unshaded area.

11

42/21

75

42/21

110

42/21

144

42/21

190

40/20

265

40/20

319

38/19

417

36/18

525

36/18

620

36/18

746

34/17

900

34/17

1036

34/17

1163

32/16

1566

32/16

1883

12

38/19

80

40/20

115

40/20

154

40/20

202

38/19

280

38/19

345

36/18

441

34/17

550

34/17

659

34/17

786

32/16

950

32/16

1096

32/16

1230

30/15

1660

30/15

1993

26/13

3300

26/13

3580

26/13

3870

24/12

5520

22/11

8110

13

38/19

80

38/19

120

38/19

166

36/18

220

36/18

290

36/18

360

34/17

470

32/16

600

32/16

710

30/15

880

30/15

1010

30/15

1160

28/14

1390

1660
1760

26/13

2300

24/12

3540

24/12

3840

24/12

4150

22/11

5960

20/10

8820

14

34/17

90

34/17

130

34/17

180

34/17

230

34/17

300

34/17

380

32/16

500

30/15

630

30/15

750

28/14

930

28/14

1070

26/13

1310

26/13

1480

26/13

1870

24/12

2460

22/11

3820

22/11

4150

22/11

4480

20/10

6480

18/9

9680

15

32/16

95

32/16

140

32/16

190

32/16

250

32/16

320

32/16

400

30/15

520

28/14

670

28/14

790

26/13

990

26/13

1140

24/12

1400

24/12

1590

24/12

2000

22/11

2650

22/11

3820

20/10

4500

20/10

4870

18/9

7120

18/9

9680

16

30/15

100

30/15

150

30/15

205

30/15

260

28/14

360

28/14

450

28/14

550

28/14

670

26/13

840

24/12

1060

24/12

1220

24/12

1400

22/11

1710

22/11

2160

20/10

2880

20/10

4150

20/10

4500

18/9

5340

18/9

7120

16/8

10760

17

28/14

106

28/14

160

28/14

215

26/13

290

26/13

380

26/13

480

26/13

590

26/13

710

24/12

900

24/12

1060

22/11

1320

22/11

1510

20/10

1860

20/10

2350

20/10

2880

18/9

4550

18/9

4950

18/9

5340

16/8

7910

16/8

10760

18

26/13

110

26/13

170

24/12

240

24/12

310

24/12

400

24/12

510

24/12

630

24/12

760

24/12

900

22/11

1140

22/11

1320

20/10

1640

20/10

1860

18/9

2570

18/9

3170

16/8

5060

16/8

5500

16/8

5940

16/8

7910

14/7

12150

19

24/12

180

24/12

240

22/11

340

22/11

440

22/11

550

22/11

680

22/11

820

22/11

970

22/11

1140

20/10

1430

20/10

1640

18/9

2040

18/9

2570

16/8

3520

16/8

5060

16/8

5500

16/8

5940

14/7

8920

14/7

12150

20

22/11

190

22/11

260

22/11

340

22/11

440

22/11

550

20/10

740

20/10

890

20/10

1060

20/10

1240

20/10

1430

18/9

1800

18/9

2040

16/8

2860

16/8

3520

14/7

5710

14/7

6200

14/7

6710

14/7

8920

12/6

13990

21

20/10

370

20/10

470

20/10

600

20/10

740

20/10

890

20/10

1060

20/10

1240

18/9

1570

18/9

1800

16/8

2270

16/8

2860

14/7

3970

14/7

5710

14/7

6200

14/7

6710

12/6

10280

12/6

13990

22

18/9

400

18/9

520

18/9

660

18/9

810

18/9

970

18/9

1160

18/9

1360

18/9

1570

16/8

2000

16/8

2270

16/8

2860

14/7

3970

12/6

6580

12/6

7140

12/6

7730

12/6

10280

23

CUT-LOK only if

Dia. and number of

rings are in bottom

shaded area.

18/9

400

18/9

520

16/8

730

16/8

900

16/8

1080

16/8

1290

16/8

1510

16/8

1740

16/8

2000

16/8

2270

14/7

3230

14/7

3970

12/6

6580

12/6

7140

12/6

7730

24

16/8

450

16/8

580

16/8

730

16/8

900

16/8

1080

16/8

1290

16/8

1510

16/8

1740

16/8

2000

14/7

2560

14/7

3230

12/6

4570

12/6

6580

12/6

7140

25

14/7

500

14/7

650

14/7

820

14/7

1010

14/7

1220

14/7

1450

14/7

1700

14/7

1960

14/7

2260

14/7

2560

14/7

3230

12/6

4570

26

14/7

820

14/7

1010

14/7

1220

14/7

1450

14/7

1700

14/7

1960

14/7

2260

14/7

2560

12/6

3720

12/6

4570

27

12/6

950

12/6

1160

12/6

1410

12/6

1670

12/6

1960

12/6

2260

12/6

2600

12/6

2950

12/6

3720

12/6

4570

Corrugated floors and monorail

supports are required if Dia. and

number of rings are in bottom

unshaded area.

28

12/6

950

12/6

1160

12/6

1410

12/6

1670

12/6

1960

12/6

2260

12/6

2600

12/6

2950

12/6

3720

29

12/6

950

12/6

1160

12/6

1410

12/6

1670

12/6

1960

SUPPORT SPACING
SUPPORT QUANTITY

Floor styles list in order of

increasing strength

20 Gauge COR-LOK
18 Gauge COR-LOK

CUT-LOK

All floor styles OK for

bin sizes in upper

shaded area.

SUPPORT SPACING

SUPPORT QUANTITY

Advertising