Grain Systems Bin Flooring PNEG-1567 User Manual

Page 8

Advertising
background image

2. Recommended Method for Full Floor Installation

8

PNEG-1567 54' Cor-Lok and Cut-Lok Flooring

Grain Systems Recommended Method for Full Floor Installation

Using the GSI recommended method for full floor installation should save construction time and eliminate
the problem of improper installation which could invalidate your warranty. Note the following dimensions
as shown in

Figure 2B.

• Dimension “A” is the leg-to-leg spacing along the centerline of a given plank.

• Dimension “B” is the amount of stagger between supports under adjacent planks and is half

of Dimension “A”.

• Dimension “C” is the distance from the center of the unload auger to the nearest rows of supports and

is half of Dimension “B”.

Dimensions “A”, “B” and “C” are shown on the appropriate grandstand layout for wall heights under 32'.
For taller bins, grandstand quantity as well as Dimensions “A” and “B” are given on

Page 17

and

Page 18

for 20 gauge.

1. Layout centerlines of tank being sure one centerline is in line with the direction of the flooring planks

while the other centerline is perpendicular with the flooring planks.

(See Figure 2B.)

2. Measure over “C” Dimension from centerline that is perpendicular to the direction of the flooring

planks. Do this at each end of the bin. Strike a chalk line here.

(See Figure 2B.)

3. Measure over “B” Dimension from the previously (chalked in step #2) and strike a chalk line here.

Continue this procedures until the bin wall is reached in both directions.

(See Figure 2B.)

Figure 2B

Chalked lines referred to

Step 2.

Advertising