1/2 x 1-3/4 in. flange bolt (S-10252)
G
1/2 in. flange nut (S-10253)
D
Center collar splice plate (CTR-0124)
4. Locate the column of three holes (K) that are not paired together on the inside radius of the center
collar, and install a center collar channel clip (H).
5. Secure with flange bolts (I) and flange nuts (J).
6. Repeat this procedure for the remaining three center collar channel clips (H).
Figure 7-16 Installing center collar channel clips
H
Center collar channel clip (CTR-0083)
J
1/2 in. flange nut (S-10253)
I
1/2 x 1-3/4 in. flange bolt (S-10252)
K
Row of three holes
7. Tighten all of the hardware to the recommended torque specifications, see
.