Shinko Controller

Setup (056-1954-9)

Introduction

Depending on the input settings, the Shinko Controller (056-1954-9) can be set up for three (3) possible
configurations. Refer to charts

on Page 2

for the input settings to designate the controller.

Instructions

Figure 1

Programming Sub Setting Mode

1. Power-up the unit.

2. Press UP ARROW and simultaneously press the MODE KEY (Basic Setting Mode).

3. Use arrow keys to change the setting values.

4. Set setting values for the controller type according the programming table.

5. Press MODE KEY to enter setting and step to the next function.

6. Repeat

Step 3

through

Step 5

until all modes “PROP BAND” through “PROP CYCLE” are

properly set.

Programming Auxiliary Function Mode 2

7. Simultaneously press DOWN ARROW and the MODE KEY for approximately 3 second or until

“Loct” is displayed (Auxiliary Setting Mode).

8. Repeat

Step 3

through

Step 5

until all modes “VALUE LOC” through “OUTPUT HYST” are set.

NOTE: Basic setting modes cannot be changed when the value lock is set as 1, 2 or 3.

9. Change lock value to “LOCK 2” when finished programming.