PNEG-010 Vane Axial Fan

3. Installation Instructions

Vane Axial Fan Pad

Placement of the Fan Pad: Transitions/Fans/Heaters Only

If a fan or fan and heater is to be installed, refer to

Figure 3A

to determine the concrete pad size.

1. The top of this pad should be level with the top of the bin’s foundation.

2. Recommended pad thickness is 4" minimum.

3. Front of pad should be perpendicular to bin wall.

4. Pad for heater not required, but if it is to added, pour the pad to cover both locations.

For fans and transitions used in aeration duct system applications, refer the transition and aeration
installation instructions.

IMPORTANT: Fan pad and fan must be level and smooth for proper operation. Vibration problems can

result from improper fan leveling.

Figure 3A

TR-4734
A = 20" for fans without heaters
A = 44'' for fans with heaters

TR-6918 and TR-6919
A = 32" for fans without heaters
A = 56" for fans with heaters

TR-7048
A = 45" for fans without heaters
A = 69" for fans with heaters