4" wcl commercial tank stiffener instructions, Notice – Grain Systems Tanks PNEG-1400 User Manual

Page 29

Advertising
background image

PNEG-1400 WCL Commercial 4" Corrugation Externally Stiffened Grain Bin

29

4. 4" WCL Commercial Tank Stiffener Instructions

4" WCL Corrugation WCL Commercial Stiffener Splice Details

WCL tank stiffeners will be mounted on the outside of the tank.

The non-offset stiffeners that splice with a splice plate, must not overlap. Contact GSI if overlapping is
observed during construction.

When installing bottom stiffeners, the stiffener with base plate attached may not rest on the foundation
(due to unlevel foundation, etc.). If this happens, use the shim plates that are provided to fill any openings
between the base plate and concrete.

Stiffener Color Code Chart

NOTE: Some colors are different than those used for sidewall sheets.

Stiffener Gauge

Color Code

15

Red

14

Green

13

Dark Blue

12

Black

11

Pink

10

Light Blue

9

Purple

8

Yellow

5

Fluorescent Green

5+12

Gold/Black

5+10

Gold/Light Blue

5+8

Gold/Yellow

5+5

Gold/White

NOTICE

If shim plates are not used where required, the downward pressure of the stiffeners
will not be transferred directly to the foundation and bin failure could result.