Wire Grill Guard Roof Vent

Wire Grill Guard Roof Vent Assembly and Installation Instructions

The following instructions are for assembling and installing the wire grill guard roof vent. Before beginning
assembly, check the packing list to ensure all components have been received. The unit is easiest
assembled in the upside down position as shown in

Figure 1.

Locate the roof vent as shown in

Figure 5.

Assembly

1. Turn one (1) roof vent housing (MIS-6778) upside down.

(See Figure 1.)

2. Insert 5/16" x 1-1/4" bin bolt with neoprene washer through the hole in the side of the roof vent. Place

jamb nut onto the bolt and tighten.

(See Figure 1.)

3. Slide one eyelet of grill guard onto the 5/16" bin bolt.

4. Insert 5/16" x 1-1/4" bin bolt with neoprene washer through the other side of the roof vent, through

jamb nut and other eyelet of grill guard. Tighten nut against vent housing side.

5. Apply a bead of tube caulking around the three (3) housing sides of the roof vent where it meets the

hold down angle.

6. Place hold down angle (MIS-4404) on the assembled roof vent. The wide end of the hold down angle

must face the vent discharge. Once aligned, screw nine (9) #10 self drilling (S-280) screws through
the roof housing and into the hold down angle.

(See Figure 2.)