Attachment Locations of Purlins to Rafters
Purlins are horizontal members between the rafters that give support to the roof structure. The length of
the purlin determines its location on the A-frame assembly.
The following reference depicts a completely assembled A-frame roof rafter section with X-bracing
installed. For more information, see the following sections:
Assembling Purlin Number 1, page 95
bling Purlin Number 2, page 93
,
Assembling Purlin Number 3, page 90
,
Assembling Purlin Number 5, page 86
, and
Assembling Purlin Number 6, page 84
Figure 7-12 Location of purlins for a 90 ft (27.4 m) and 105 ft (32 m) diameter bins
A
Location of purlin number 1 (CTR-0005)
D
Location of purlin number 4 (CTR-0008)
B
Location of purlin number 2 (CTR-0006)
E
Location of purlin number 5 (CTR-0009)
C
Location of purlin number 3 (CTR-0007)
F
Location of purlin number 6 (CTR-0010)
Pneg-4090 90 Ft Diameter 40-Series Bin
83