8. Locate the spigot into the clamps provided. Loosen nuts – slide spigot in – retighten clamps. Note the spigot can be

mounted in either the left or the right side. SEE FIG 3

9. Shut off Main Water Supply.
10. Assemble compression fitting to Spadewell spigot. Then plumb into water supply line. Compression fitting has 1/4NPT

thread.

11. Connect Spadewell drain to drain line in store.
12. Turn Main Water Supply Line on and check for leaks.
13. Place divider into well and position bumper onto rim
14. Clean unit. Wipe excess sealant or caulk that may have spread out during installation.
15. Turn on water – adjust for proper flow – Unit is now ready for use.

Advertising