Installing a rear i/o module, Installing a rear i/o module -2 – Cobalt Digital COMPASS 9121 3G_HD_SD-SDI_ASI Redundancy Switch User Manual

Page 16

Advertising
background image

2

Installing a Rear I/O Module

2-2

9121 PRODUCT MANUAL

9121-OM (V1.2)

Installing a Rear I/O Module

Install a Rear I/O Module as follows:

1.

On the frame, determine the slot in which the 9121 is to be installed.

2.

In the mounting area corresponding to the slot location, install
Rear I/O Module as shown in Figure 2-1.

Table 2-1

9121 Rear I/O Modules

9121 Rear I/O Module

Description

RM20-9121-B

Provides the following connections:

IN A BNC input

IN B BNC input

RLY A/B OUT passive relay-coupled output.

Failover to IN B if IN A is invalid. Manually selected
via user controls or SNMP.

Note: Relay output must be terminated into 75

impedance via connection to downstream
equipment or termination for card to properly
display input status.

• Four non-relay outputs (OUT 1-1, 1-2, 1-3, and

OUT 2) with defeatable reclocking. All four
non-relay outputs track with RLY A/B OUT
selection.

• GPI inputs GPI1/G and GPI2/G for manual

selection of inputs IN A or IN B.

- GPI 1 invokes IN A
- GPI 2 invokes IN B

• GPI outputs GPO1 and GPO2 indicate input

channel selection (either invoked manually or via
failover).

- GPO 1 pair closed when IN A is selected
- GPO 2 pair closed when IN B is selected

CAUTION

GPO controlled circuit must not exceed voltage/
current ratings. See Technical Specifications (p. 1-6)
in Chapter 1, Introduction.