Rainbow Electronics RC1090 User Manual

Page 3

Advertising
background image

RC1040/1080/1090

2005 Radiocrafts AS

RC1040/RC1080/RC1090 Data Sheet (rev. 1.3)

Page 3 of 17

Pin Assignment

GND

CTS/RXEN/RXTX

RTS/TXEN

CONFIG

TXD/SCL

RXD/SDA

GND

GND

VCC

ON/OFF

VDD

GND

RF

GND

1

2

3

4

5

6

7

14

13

12

11

10

9

8

15 16 17 18 19 20 21 22

30 29 28 27 26 25 24 23

Pin Description

Pin no Pin name

Description

1

GND

System ground

2

CTS/RXTX/RXEN UART Clear to Send, UART RXTX, Receive Mode Enable, or SLEEP

mode activation. Connect to VDD if not used. Internal 100 k series

resistor.

3

RTS/TXEN

UART Request to Send, Transmit Mode Enable, or SLEEP mode

activation. Connect to VDD if not used. Internal 100 k series

resistor.

4

CONFIG

Configuration Enable. Active low. Should normally be set high.

Connect to VDD if not used. Internal 100 k series resistor.

5

TXD/SCL

UART TX Data, or serial data clock. Internal 100 k series resistor.

6

RXD/SDA

UART RX Data, or serial data I/O. Internal 100 k series resistor.

7

GND

System ground

8

GND

System ground

9

RF

RF I/O connection to antenna

10

GND

System ground

11

VDD

Supply voltage output, regulated. Should normally be left open

12

ON/OFF

Module on/off (shutdown). ON when high, OFF when low. See

important note under Power Management page 5.

13

VCC

Supply voltage input. Internally regulated. Maximum rise-time

requirement apply, see Electrical Specification.

14

GND

System ground

15-18 RESERVED

Test pins or pins reserved for future use.

Do not connect!

19

RSSI

Received signal strength indicator, analogue output

20-21 RESERVED

Test pins or pins reserved for future use.

Do not connect!

22

RESET

Main reset (active low). Should normally be left open. Internal 100 k

pull-up resistor, no series resistor.

23-30 RESERVED

Test pins or pins reserved for future use.

Do not connect!

Note 1: In UART mode the TXD and RXD are used for serial data, and CTS/RXTX and RTS for flow control

(optional). If flow control is not used, and RXEN and TXEN are both asserted (active low) the module is set in SLEEP

mode. RXEN and TXEN should be connected to VDD if not used if not used for SLEEP mode activation. A pull-up

resistor is not necessary due to an internal series resistor.

Note 2: In synchronous mode the SCL (data clock) and SDA (Data input and output) are used for serial data.

The RXEN and TXEN pins are then used to select the operation mode of the device. Signals are active low.

Note 3: The CONFIG pin is used to enter configuration mode (change of default settings). Active low.

Note 4: Do not use VDD for supply to external circuits. Should only be used for RXEN and TXEN pull-up, if required.

Note 5: RXEN, TXEN, CONFIG, TXD and RXD have internal 100 k series resistors.

Note 6: Other digital interfaces may be specified upon request.

Advertising