ON/OFF is turned low, and keep low until ON/OFF is high again (VCC – 10%). This

will ensure proper power-on reset (POR).

If a dedicated I/O pin for the RESET signal is not available, a 10 kOhm series resistor

from ON/OFF to RESET can be used, and controlling ON/OFF with a 3 / 5V signal

from the MCU. This is valid for the RC12x0-series only. For the RC10x0-modules

direct control of the RESET-pin must be used

Use an external POR and brown-out supervisory circuit. The circuit should be

connected between VDD and GND, controlling RESET. This solution will force

RESET low as long as VDD is below the threshold voltage. The RESET has an

internal pull-up resistor to VDD, thus an open-drain output supervisory circuit can be

used. A threshold voltage of 2.5 V is recommended. Supervisory circuits at 2.5V are

for example MAX803 and MAX6328.

As noted in the Pin Description, RXEN (CTS/RXTX), TXEN (RTS) and CONFIG pins should

have their pull-ups connected to VDD, not VCC. If RXEN is used as CTS (hardware

handshake) or as RXTX (RS485) output, no pull-up is required and should be avoided as this

reduce the voltage swing due to the internal resistor.