Table 3. command byte definition – Rainbow Electronics MAX7473 User Manual

Page 12

Advertising
background image

MAX7472/MAX7473

HDTV Anti-Aliasing Filters with Triple-Input Mux

12

______________________________________________________________________________________

COMMAND BYTE: INDIVIDUAL BIT DEFINITIONS

C7

C6

C5

C4

C3

C2

C1

C0

DESCRIPTION

0

0

0

0

0

0

0

0

Power-down.

0

0

0

0

0

0

0

1

Wake-up; resume normal operation using the frequency/status previously
stored (unless power has been cycled).

0

0

0

0

0

0

1

0

Set clamp voltage level for IN1 to low.

0

0

0

0

0

0

1

1

Set clamp voltage level for IN1 to high.

0

0

0

0

0

1

0

0

Set clamp voltage level for IN2 to low.

0

0

0

0

0

1

0

1

Set clamp voltage level for IN2 to high.

0

0

0

0

0

1

1

0

Set clamp voltage level for IN3 to low.

0

0

0

0

0

1

1

1

Set clamp voltage level for IN3 to high.

0

0

0

0

1

0

0

0

Select component input, color-burst filter disabled.

0

0

0

0

1

0

0

1

Select composite input, color-burst filter enabled.

0

0

0

0

1

0

1

0

Select internal sync.

0

0

0

0

1

0

1

1

Select external sync.

0

0

0

0

1

1

0

0

Select positive polarity for the external sync.

0

0

0

0

1

1

0

1

Select negative polarity for the external sync.

0

0

0

0

1

1

1

0

Enable filters.

0

0

0

0

1

1

1

1

Disable filters. Enter bypass mode.

0

0

0

1

0

0

0

0

Reset status to the default status as outlined in the Control/Status register
table. This command does not affect the Frequency register and the Channel
Selection register.

0

0

0

1

0

0

0

1

Request reading the Control/Status register. The interface expects an Sr
condition to follow with address and read/write set to read so that data can be
driven onto the bus.

0

0

0

1

0

0

1

0

Load the Frequency register with the data byte following the command word.

0

0

0

1

0

0

1

1

Request reading the Frequency register. The interface expects an Sr
condition to follow with address and read/write set to read so that data can be
driven onto the bus.

0

0

0

1

0

1

0

0

Select Input A.

0

0

0

1

0

1

0

1

Select Input B.

0

0

0

1

0

1

1

0

Select Input C.

0

0

0

1

0

1

1

1

Request reading the Channel Selection register. The interface expects an Sr
condition to follow with address and read/write set to read so that data can be
driven onto the bus.

Table 3. Command Byte Definition

Advertising