Read cycle timing parameters, Byte/page-write cycle timing parameters – Rainbow Electronics W29EE011 User Manual

Page 11

Advertising
background image

W29EE011

Publication Release Date: July 1999

- 11 - Revision A12

Read Cycle Timing Parameters

(V

CC

= 5.0V

±

10

%

, V

CC

= 5.0

±

5

%

for 70 nS, V

SS

= 0V, T

A

= 0 to 70

°

C)

PARAMETER

SYM.

W29EE011-90

W29EE011-15

UNIT

MIN.

MAX.

MIN.

MAX.

Read Cycle Time

T

RC

90

-

150

-

nS

Chip Enable Access Time

T

CE

-

90

-

150

nS

Address Access Time

T

AA

-

90

-

150

nS

Output Enable Access Time

T

OE

-

45

-

70

nS

CE

Low to Active Output

T

CLZ

0

-

0

-

nS

OE

Low to Active Output

T

OLZ

0

-

0

-

nS

CE

High to High-Z Output

T

CHZ

-

45

-

45

nS

OE

High to High-Z Output

T

OHZ

-

45

-

45

nS

Output Hold from Address Change

T

OH

0

-

0

-

nS

Byte/Page-write Cycle Timing Parameters

PARAMETER

SYMBOL

MIN.

TYP.

MAX.

UNIT

Write Cycle (Erase and Program)

T

WC

-

-

10

mS

Address Setup Time

T

AS

0

-

-

nS

Address Hold Time

T

AH

50

-

-

nS

WE and CE Setup Time

T

CS

0

-

-

nS

WE and CE Hold Time

T

CH

0

-

-

nS

OE High Setup Time

T

OES

10

-

-

nS

OE High Hold Time

T

OEH

10

-

-

nS

CE Pulse Width

T

CP

70

-

-

nS

WE Pulse Width

T

WP

70

-

-

nS

WE High Width

T

WPH

150

-

-

nS

Data Setup Time

T

DS

50

-

-

nS

Data Hold Time

T

DH

10

-

-

nS

Byte Load Cycle Time

T

BLC

0.22

-

200

µ

S

Byte Load Cycle Time-out

T

BLCO

300

-

-

µ

S

Note: All AC timing signals observe the following guidelines for determining setup and hold times: