Command codes for software data protection, Sofware data protection acquisition flow – Rainbow Electronics W29EE011 User Manual

Page 6

Advertising
background image

W29EE011

- 6 -

Command Codes for Software Data Protection

BYTE SEQUENCE

TO ENABLE PROTECTION

TO DISABLE PROTECTION

ADDRESS

DATA

ADDRESS

DATA

0 Write

5555H

AAH

5555H

AAH

1 Write

2AAAH

55H

2AAAH

55H

2 Write

5555H

A0H

5555H

80H

3 Write

-

-

5555H

AAH

4 Write

-

-

2AAAH

55H

5 Write

-

-

5555H

20H

Sofware Data Protection Acquisition Flow

Software Data Protection
Enable Flow

Load data AA

to

address 5555

Load data 55

to

address 2AAA

Load data A0

to

address 5555

Load data AA

to

address 5555

Load data 55

to

address 2AAA

Load data 80

to

address 5555

Load data AA

to

address 5555

Load data 55

to

address 2AAA

Load data 20

to

address 5555

Software Data Protection
Disable Flow

Pause 10 mS

Exit

Sequentially load

up to 128 bytes

of page data

Pause 10 mS

Exit

(Optional page

load operation)

Notes for software program code:

Data Format: DQ7

DQ0 (Hex)

Address Format: A14

A0 (Hex)

Advertising