AC Characteristics, continued

Read Cycle Timing Parameters

(V

DD

= 5.0V

±

10

%

for 90 nS and 120 nS; V

DD

= 5.0V

±

5% for 70 nS, V

SS

= 0V, T

A

= 0 to 70

°

C)

PARAMETER

SYM.

W29C020C-70 W29C020C-90 W29C020C-12 UNIT

MIN.

MAX.

MIN.

MAX.

MIN.

MAX.

Read Cycle Time

T

RC

70

-

90

-

120

-

nS

Chip Enable Access Time

T

CE

-

70

-

90

-

120

nS

Address Access Time

T

AA

-

70

-

90

-

120

nS

Output Enable Access Time

T

OE

-

35

-

40

-

50

nS

CE High to High-Z Output

T

CHZ

-

25

-

25

-

30

nS

OE High to High-Z Output

T

OHZ

-

25

-

25

-

30

nS

Output Hold from Address change

T

OH

0

-

0

-

0

-

nS

Byte/Page-write Cycle Timing Parameters

PARAMETER

SYMBOL

MIN.

TYP.

MAX.

UNIT

Write Cycle (erase and program)

T

WC

-

-

10

mS

Address Setup Time

T

AS

0

-

-

nS

Address Hold Time

T

AH

50

-

-

nS

WE and CE Setup Time

T

CS

0

-

-

nS

WE and CE Hold Time

T

CH

0

-

-

nS

OE High Setup Time

T

OES

0

-

-

nS

OE High Hold Time

T

OEH

0

-

-

nS

CE Pulse Width

T

CP

70

-

-

nS

WE Pulse Width

T

WP

70

-

-

nS

WE High Width

T

WPH

100

-

-

nS

Data Setup Time

T

DS

50

-

-

nS

Data Hold Time

T

DH

0

-

-

nS

Byte Load Cycle Time

T

BLC

-

-

150

µ

S

Note: All AC timing signals observe the following guideline for determining setup and hold times:

Reference level is V

IH

for high-level signal and V

IL

for low-level signal.

Advertising