Rainbow Electronics W29C020C User Manual

Page 8

Advertising
background image

W29C020C

- 8 -

Command Codes for Product Identification and Boot Block Lockout Detection

BYTE

SEQUENCE

ALTERNATE PRODUCT (7)

IDENTIFICATION/BOOT BLOCK

LOCKOUT DETECTION ENTRY

SOFTWARE PRODUCT

IDENTIFICATION/BOOT BLOCK

LOCKOUT DETECTION ENTRY

SOFTWARE PRODUCT

IDENTIFICATION/BOOT BLOCK

LOCKOUT DETECTION EXIT

ADDRESS

DATA

ADDRESS

DATA

ADDRESS

DATA

0 Write

5555

AA

5555H

AAH

5555H

AAH

1 Write

2AAA

55

2AAAH

55H

2AAAH

55H

2 Write

5555

90

5555H

80H

5555H

F0H

3 Write

-

-

5555H

AAH

-

-

4 Write

-

-

2AAAH

55H

-

-

5 Write

-

-

5555H

60H

-

-

Pause 10

µ

S

Pause 10

µ

S

Pause 10

µ

S

Software Product Identification and Boot Block Lockout Detection Acquisition Flow

Product
Identification
Entry (1)

Load data AA

to

address 5555

Load data 55

to

address 2AAA

Load data 80

to

address 5555

Load data AA

to

address 5555

Load data 55

to

address 2AAA

Load data 60

to

address 5555

Product
Identification
and Boot Block
Lockout Detection
Mode (3)

Read address = 00000

data = DA

Read address = 00001

data = 45

Read address = 00002

data = FF/FE

(4)

Read address = 3FFF2

data = FF/FE

(5)

Product
Identification
Exit (1)

Load data AA

to

address 5555

Load data 55

to

address 2AAA

Load data F0

to

address 5555

Pause 10 S

Normal Mode

(6)

(2)

(2)

Pause 10 S

µ

µ

Notes for software product identification/boot block lockout detection:

(1) Data Format: DQ7

DQ0 (Hex); Address Format: A14

A0 (Hex)

(2) A1

A16 = V

IL

; manufacture code is read for A0 = V

IL

; device code is read for A0 = V

IH

.

(3) The device does not remain in identification and boot block (address 0002 Hex/3FFF2 Hex respond to first 8K/last 8K) lockout detection
mode if

power down.

(4), (5) If the output data is "FF Hex," the boot block programming lockout feature is activated; if the output data "FE Hex," the lockout feature
is

inactivated and the block can be programmed.

(6) The device returns to standard operation mode.