Table 4. i, C register: mode1 – Rainbow Electronics MAX8649 User Manual

Page 22

Advertising
background image

MAX8649

1.8A Step-Down Regulator with Differential
Remote Sense in 2mm x 2mm WLP

22

______________________________________________________________________________________

REGISTER NAME

MODE1

Address

0x01h

Reset Value

0x1Eh

Type

Read/write

Special Features

Reset upon V

DD

or IN1 UVLO

BIT

NAME

DESCRIPTION

DEFAULT

VALUE

B7 (MSB)

OPERATION_MODE1

DC-DC Step-Down Converter Operation Mode for MODE1
0 = D C - D C conver ter autom ati cal l y chang es b etw een hyster eti c m od e for

l i g ht l oad cond i ti ons and P WM m od e for m ed i um to heavy l oad cond i ti ons.

1 = DC-DC converter operates in forced-PWM mode.

0

B6

SYNC_MODE1

Disable/Enable Synchronization to External Clock
0 = DC-DC converter ignores the external SYNC input regardless of

operation mode.

1 = D C - D C conver ter synchr oni zes to exter nal S Y N C i np ut w hen avai l ab l e.

0

B5

B4

B3

B2

B1

B0 (LSB)

OUT_MODE1[5:0]

Output Voltage Selection for MODE1
000000 = 0.75V
000001 = 0.76V
011101 = 1.04V
011110 = 1.05V
011111 = 1.06V
111110 = 1.37V
111111 = 1.38V

011110

Table 4. I

2

C Register: MODE1

This register contains output voltage and operation mode control for MODE1, VID1 = GND, VID0 = V

DD

.