Table 5. i, C register: mode2 – Rainbow Electronics MAX8649 User Manual

Page 23

Advertising
background image

MAX8649

1.8A Step-Down Regulator with Differential

Remote Sense in 2mm x 2mm WLP

______________________________________________________________________________________

23

REGISTER NAME

MODE2

Address

0x02h

Reset Value

0xB0h

Type

Read/write

Special Features

Reset upon V

DD

or IN1 UVLO

BIT

NAME

DESCRIPTION

DEFAULT

VALUE

B7 (MSB)

OPERATION_MODE2

DC-DC Step-Down Converter Operation Mode for MODE2
0 = D C - D C conver ter autom ati cal l y chang es b etw een hyster eti c m od e for

l i g ht l oad cond i ti ons and P WM m od e for m ed i um to heavy l oad cond i ti ons.

1 = DC-DC converter operates in forced-PWM mode.

1

B6

SYNC_MODE2

Disable/Enable Synchronization to External Clock
0 = DC-DC converter ignores the external SYNC input regardless of

operation mode.

1 = D C - D C conver ter synchr oni zes to exter nal S Y N C i np ut w hen avai l ab l e.

0

B5

B4

B3

B2

B1

B0 (LSB)

OUT_MODE2[5:0]

Output Voltage Selection for MODE2
000000 = 0.75V
000001 = 0.76V
101110 = 1.21V
101111 = 1.22V
110000 = 1.23V
111110 = 1.37V
111111 = 1.38V

110000

Table 5. I

2

C Register: MODE2

This register contains output voltage and operation mode control for MODE2, VID1 = V

DD

, VID0 = GND.

Advertising