Ac electrical characteristics – Rainbow Electronics DS1339 User Manual

Page 16

Advertising
background image

DS1339

16 of 18

AC ELECTRICAL CHARACTERISTICS

(V

CC

= MIN to MAX, T

A

= -40

°C to +85°C) (Note 12)

PARAMETER

SYMBOL CONDITION

MIN

TYP

MAX UNITS NOTES

Fast Mode

100

400

SCL Clock
Frequency

f

SCL

Standard Mode

100

kHz

Fast Mode

1.3

Bus Free Time
Between a STOP
and START
Condition

t

BUF

Standard Mode

4.7

ms

Fast Mode

0.6

Hold Time
(Repeated) START
Condition

t

HD:STA

Standard Mode

4.0

ms

5

Fast Mode

1.3

LOW Period of
SCL Clock

t

LOW

Standard Mode

4.7

ms

Fast Mode

0.6

HIGH Period of
SCL Clock

t

HIGH

Standard Mode

4.0

ms

Fast Mode

0.6

Setup Time for a
Repeated START
Condition

t

SU:STA

Standard Mode

4.7

ms

Fast Mode

0

0.9

Data Hold Time

t

HD:DAT

Standard Mode

0

ms

6, 7

Fast Mode

100

Data Setup Time

t

SU:DAT

Standard Mode

250

ns

9

Fast Mode

300

Rise Time of Both
SDA and SCL
Signals

t

R

Standard Mode

20 + 0.1C

B

1000

ns

8

Fast Mode

Fall Time of Both
SDA and SCL
Signals

t

F

Standard Mode

20 + 0.1C

B

300

ns

8

Fast Mode

0.6

Setup Time for
STOP Condition

t

SU:STO

Standard Mode

4.0

ms

Capacitive Load for
Each Bus Line

C

B

400

pF

8

I/O Capacitance

C

I/O

10

pF

Oscillator Stop Flag
(OSF) Delay

t

OSF

100

ms

11

Advertising