Figure 2. DS1339 TIMEKEEPER REGISTERS

ADDRESS

BIT7

BIT6

BIT5

BIT4

BIT3

BIT2

BIT1

BIT0

FUNCTION

RANGE

00H

0

10 SECONDS

SECONDS

Seconds

00–59

01H

0

10 MINUTES

MINUTES

Minutes

00–59

AM/PM

02H

0

12/24

10HR

10HR

HOUR

Hours

1–12 +

AM/PM

00–23

03H

0

0

0

0

0

DAY

Day

1–7

04H

0

0

10 DATE

DATE

Date

00–31

05H

CENTURY

0

0

10 MO

MONTH

Month/

Century

01–12 +

Century

06H

10 YEAR

YEAR

Year

00–99

07H

A1M1

10 SECONDS

SECONDS

Alarm 1

Seconds

00–59

08H

A1M2

10 MINUTES

MINUTES

Alarm 1

Minutes

00–59

AM/PM

09H

A1M3

12/24

10HR

10HR

HOUR

Alarm 1

Hours

1–12 +

AM/PM

00-23

0AH

A1M4

DY/DT

10 DATE

DAY

DATE

Alarm 1

Day

Alarm 1

Date

1–7

1–31

0BH

A2M2

10 MINUTES

MINUTES

Alarm 2

Minutes

00–59

AM/PM

0CH

A2M3

12/24

10HR

10HR

HOUR

Alarm 2

Hours

1–12 +

AM/PM

00–23

0DH

A2M4

DY/DT

10 DATE

DAY

DATE

Alarm 2

Day

Alarm 2

Date

1–7

1–31

0EH

EOSC

0

BBSQI

RS2

RS1

INTCN

A2IE

A1IE

Control

0FH

OSF

0

0

0

0

0

A2F

A1F

Status

10H

TCS3

TCS2

TCS1

TCS0

DS1

DS0

ROUT1

ROUT0

Trickle

Charge


Note:
Unless otherwise specified, the registers’ state are not defined when power is first applied or V

CC

and V

BACKUP

falls below the V

BACKUP

min.

Advertising