AT17LV65/128/256/512/010/002/040

2321D–CNFG–10/02

Notes:

1. AC test lead = 50 pF.
2. Float delays are measured with 5 pF AC loads. Transition is measured ± 200 mV from steady-state active levels.

Notes:

1. AC test lead = 50 pF.
2. Float delays are measured with 5 pF AC loads. Transition is measured ± 200 mV from steady-state active levels.

AC Characteristics

V

CC

= 5V ± 5% Commercial; V

CC

= 5V ± 10% Industrial

Symbol

Description

AT17LV65/128/256

AT17LV512/010/002/040

Units

Commercial

Industrial

Commercial

Industrial

Min

Max

Min

Max

Min

Max

Min

Max

T

OE

(1)

OE to Data Delay

30

35

30

35

ns

T

CE

(1)

CE to Data Delay

45

45

45

45

ns

T

CAC

(1)

CLK to Data Delay

50

55

50

50

ns

T

OH

Data Hold from CE, OE, or CLK

0

0

0

0

ns

T

DF

(2)

CE or OE to Data Float Delay

50

50

50

50

ns

T

LC

CLK Low Time

20

20

20

20

ns

T

HC

CLK High Time

20

20

20

20

ns

T

SCE

CE Setup Time to CLK (to guarantee proper
counting)

35

40

20

25

ns

T

HCE

CE Hold Time from CLK (to guarantee proper
counting)

0

0

0

0

ns

T

HOE

OE High Time (guarantees counter is reset)

20

20

20

20

ns

F

MAX

Maximum Clock Frequency

12.5

12.5

15

15

MHz

AC Characteristics when Cascading

V

CC

= 5V ± 5% Commercial; V

CC

= 5V ± 10% Industrial

Symbol

Description

AT17LV65/128/256

AT17LV512/010/002/040

Units

Commercial

Industrial

Commercial

Industrial

Min

Max

Min

Max

Min

Max

Min

Max

T

CDF

(2)

CLK to Data Float Delay

50

50

50

50

ns

T

OCK

(1)

CLK to CEO Delay

35

40

35

40

ns

T

OCE

(1)

CE to CEO Delay

35

35

35

35

ns

T

OOE

(1)

RESET/OE to CEO Delay

30

35

30

30

ns

F

MAX

Maximum Clock Frequency

10

10

12.5

12.5

MHz