The signals of the GM862-GPS MODEM serial port are:

RS232

Pin

Number

Signal

GM862-

GPS Pin

Number

Name

Usage

1

DCD -

dcd_uart

36

Data Carrier Detect

Output from the GM862-GPS that indicates the

carrier presence

2

RXD -

tx_uart

37

Transmit line *see Note

Output transmit line of GM862-GPS UART

3

TXD -

rx_uart

20

Receive line *see Note

Input receive of the GM862-GPS UART

4

DTR -

dtr_uart

43

Data Terminal Ready

Input to the GM862-GPS that controls the DTE

READY condition

5

GND

2-4

Ground

Ground

6

DSR -

dsr_uart

33

Data Set Ready

Output from the GM862-GPS that indicates the

module is ready

7

RTS -

rts_uart

45

Request to Send

Input to the GM862-GPS that controls the

Hardware flow control

8

CTS -

cts_uart

29

Clear to Send

Output from the GM862-GPS that controls the

Hardware flow control

9

RI - ri_uart

30

Ring Indicator

Output from the GM862-GPS that indicates the

incoming call condition

NOTE: According to V.24, RX/TX signal names are referred to the application side, therefore on the GM862-GPS side
these signal are on the opposite direction: TXD on the application side will be connected to the receive line (here
named TXD/ rx_uart ) of the GM862-GPS serial port and viceversa for RX.

TIP: For a minimum implementation, only the TXD and RXD lines can be connected, the other lines can be left open
provided a software flow control is implemented.