SPI Interrupt Enable Register
Register Name:SP_IER
Access Type:Write-only
•
RDRF: Receive Data Register Full Interrupt Enable
0 = No effect.
1 = Enables the receiver data register full interrupt.
•
TDRE: SPI Transmit Data Register Empty Interrupt Enable
0 = No effect.
1 = Enables the transmit data register empty interrupt.
•
MODF: Mode Fault Error Interrupt Enable
0 = No effect.
1 = Enables the mode fault interrupt.
•
OVRES: Overrun Error Interrupt Enable
0 = No effect.
1 = Enables the overrun error interrupt.