Siap-e reset status register, Siap-e clock status register – Rainbow Electronics AT75C220 User Manual

Page 15

Advertising
background image

AT75C220

15

SIAP-E Reset Status Register

Register Name: SIAP_RST
Access: Read/write
Reset Value: 0x00000001

•

RST[2:0]: Reset

These bits indicate the cause of the last reset.

SIAP-E Clock Status Register

Register Name: SIAP_CLKF
Access: Read-only
Reset Value: 0x00000001

•

CLK: Clock Status

This bit indicates which clock is in use by the system. When set, the low power clock is in use. When cleared, the PLL
is locked and the high power clock is in use. This can be used by software to determine when the power mode has
changed after the LP bit has been written.

31

30

29

28

27

26

25

24

–

–

–

–

–

–

–

–

23

22

21

20

19

18

17

16

–

–

–

–

–

–

–

–

15

14

13

12

11

10

9

8

–

–

–

–

–

–

–

–

7

6

5

4

3

2

1

0

–

–

–

–

–

RST

RST

RST

RST

Reset Event

0

0

1

Hardware

0

1

0

Watchdog Timer

1

0

0