Isd5100 – series, Configuration register 1 (cfg1) – Rainbow Electronics ISD5100 User Manual

Page 21

Advertising
background image

ISD5100 – SERIES

Publication Release Date: October, 2003

- 21 -

Revision 0.2

AGC AMP Power Down
Filter Power Down
SAMPLE RATE (& Filter) Set up (2 bits)
FILTER MUX Select
SUM 2 SUMMING AMP Control (2 bits)
SUM 1 SUMMING AMP Control (2 bits)
SUM 1 MUX Select (2 bits)
VOLUME CONTROL (3 bits)
VOLUME CONT. MUX Select (2 bits)

Configuration Register 1 (CFG1)

VLS1 VLS0 VOL2 VOL1 VOL0 S1S1 S1S0 S1M1 S1M0 S2M1 S2M0 FLS0 FLD1 FLD0 FLPD AGPD

D15 D14 D13 D12 D11 D10 D9 D8 D7 D 6 D5 D4 D3 D2 D1 D0

AGC AMP Power Down
Filter Power Down
SAMPLE RATE (& Filter) Set up (2 bits)
FILTER MUX Select
SUM 2 SUMMING AMP Control (2 bits)
SUM 1 SUMMING AMP Control (2 bits)
SUM 1 MUX Select (2 bits)
VOLUME CONTROL (3 bits)
VOLUME CONT. MUX Select (2 bits)

Configuration Register 1 (CFG1)

VLS1 VLS0 VOL2 VOL1 VOL0 S1S1 S1S0 S1M1 S1M0 S2M1 S2M0 FLS0 FLD1 FLD0 FLPD AGPD

D15 D14 D13 D12 D11 D10 D9 D8 D7 D 6 D5 D4 D3 D2 D1 D0

VLS1 VLS0 VOL2 VOL1 VOL0 S1S1 S1S0 S1M1 S1M0 S2M1 S2M0 FLS0 FLD1 FLD0 FLPD AGPD

D15 D14 D13 D12 D11 D10 D9 D8 D7 D 6 D5 D4 D3 D2 D1 D0

VLS1 VLS0 VOL2 VOL1 VOL0 S1S1 S1S0 S1M1 S1M0 S2M1 S2M0 FLS0 FLD1 FLD0 FLPD AGPD

D15 D14 D13 D12 D11 D10 D9 D8 D7 D 6 D5 D4 D3 D2 D1 D0


7.3.6. Power-up Sequence

This sequence prepares the ISD5100 Series for an operation to follow, waiting the Tpud time before
sending the next command sequence.

1. Send

I

2

C POWER UP

2.

Send one byte 10000000 {Slave Address, R/W = 0} 80h

3. Slave

ACK

4.

Wait for SCL High

5.

Send one byte 10000000 {Command Byte = Power Up} 80h

6. Slave

ACK

7.

Wait for SCL High

8. Send

I

2

C STOP

Playback Mode
The command sequence for an analog Playback operation can be handled several ways. The most
straightforward approach would be to incorporate a single four byte exchange, which consists of the
Slave Address (80h), the Command Byte (A9h) for Play Analog @ Address, and the two address
bytes.