B&B Electronics ADAM-6066 - Manual User Manual
Page 68

ADAM-6000 Series User Manual
58
Relay Output
• Channels: 6 (Form A)
• Contact rating (Resistive):
AC: 120 V @ 0.5 A
DC: 30 V @ 1 A
• Breakdown voltage: 500 VAC (50/60 Hz)
• Relay on time: 7 millisecond
• Relay off time: 3 millisecond
• Total switching time: 10 milliseconds
• Insulation Resistance: 1 G
minimum at 500 VDC
• Maximum Switching Rate: 20 operations/minute (at rated load)
• Electrical Endurance
At 12 V / 10 mA
Typical 5 x 10
7
operations
At 6 V / 100 mA
Typical 1 x 10
7
operations
At 60 V / 500 mA Typical 5 x 10
5
operations
At 30 V / 1000 mA Typical 1 x 10
6
operations
At 30 V / 2000 mA Typical 2 x 10
5
operations
• Mechanical endurance Typical 1 x 10
8
operations
• Supports pulse output (maximum 3 Hz)
General:
• Built-in Watchdog Timer
• Isolation Protection: 2000 VDC
• Power Input: Unregulated 10 ~ 30 VDC
• Power Consumption: 2 W @ 24 VDC
• Power Reversal Protection
• Operating Humidity: 5 ~ 95 % RH (non-condensing)
• Storage Humidity: 5 ~ 95 % RH (non-condensing)
• Operating Temperature: -10 ~ 60° C
• Storage Temperature: -20 ~ 80° C