Warning – Peerless-AV LCC-36S - Installation User Manual
Page 4
4 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-8 10-08-12
Drill two 5/32" (4 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Attach ceiling plate (B)
with two #14 x 2.5" (6 mm x 65 mm) wood
screws (E) as shown using 3/8" (10 mm) socket
wrench. Tighten wood screws (E) so ceiling
plate (B) is fi rmly attached.
Skip to step 2 on page 6.
Installation to Wood Joist Finished Ceilings,
Exposed Wood Joists, or Wood Beam Ceilings
• Tighten wood screws so that ceiling plate is fi rmly
attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.
• Never tighten in excess of 80 in • lb (9 N.M.).
• Make sure that mounting screws are anchored into
the center of the joist. The use of an "edge to edge"
stud fi nder is highly recommended.
WARNING
E
E
B
WOOD
JOIST
CEILING
1