1

Installation to Wood Stud Wall

Wall plate (A) can be mounted to two studs that are 16" apart. Use a stud fi nder to locate the edges of the studs.
Use of an edge-to-edge stud fi nder is highly recommended. Based on their edges, draw a vertical line down each
stud’s center. Place wall plate on wall as a template. The top mounting slots should be located 3.9" below the
desired display center. Level plate, and mark the center of the four mounting holes. Make sure that the mounting
holes are on the stud centerlines. Drill six 3/16" (5mm) dia. holes 3" (76mm) deep. Make sure that the wall plate is
level, secure it using six 3" wood screws (O) and washers (P).
Skip to step 2 on page 8.

A

O

P

• Never mount this product to metal studs without the

required accessory.

WARNING

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all

attached hardware and components.

• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder

is highly recommended.

• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.

Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).

WARNING