Warning, Aw o, Ao p w – Peerless-AV PLA50-UNLP-GB - Installation User Manual

Page 6: Installation to concrete wall 1 3 2

Advertising
background image

6 of 41

ISSUED: 06-05-06 SHEET #: 202-9140-10 (2013-10-01)

Use wall plate (A), making sure that it is level, as
a template to mark holes. The top mounting slots
should be located at your desired display center. Use
the masonry bit to drill 3/8" (10mm) dia. holes to a
minimum depth of 3" (76mm). Insert anchors (W) in
holes fl ush with wall as shown (right). Place wall plate
(A) over anchors (W) and secure with 5/16 x 3" wood
screws (O) and washers (P).

1

WARNING

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-

ware and components.

• Never exceed the Maximum Load Capacity of 150 lb (68 kg).

Installation to Concrete Wall

1

3

2

W

Drill holes and insert anchors (W).

Place plate (A) over anchors (W) and secure with screws (O).

Tighten all fasteners.

A

W

O

concrete
surface

CUT

A

W

A

Y

VIEW

INCORRECT

CORRECT

wall

plate

wall

plate

plaster/
dry wall

plaster/
dry wall

concrete

concrete

• Tighten screws so that wall plate is fi rmly attached,

but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly

to load-bearing concrete.

• Never attach concrete expansion anchors to

concrete covered with plaster, drywall, or other
fi nishing material. If mounting to concrete surfaces
covered with a fi nishing surface is unavoidable (Not
evaluated by UL), the fi nishing surface must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when
tightening screws. If plaster/drywall is thicker than
5/8" (16mm), custom fasteners must be supplied by
installer (Not evaluated by UL).

WARNING

A

O

P

W

Advertising