5.2.8 S4 Control method and slowdown mode in traveling movement application
The frequency converter can be parametrised for two different control methods. The control method options are
listed in the following table. The descriptions of the control methods are given in the section “Control methods”.
Digital inputs and the control method:
Terminal
Name
MS2
EP2
1
DI1
S1
S1
2
DI2
S2
S2
3
DI3
MS2
AP
4
DI4
S11/S21
S11/S21
5
DI5 *)
S12/S22
S12/S22
6
DI6
ES
ES
*) Note: As factory default DI5 is not in use. The stop limit signal shall be connected in series to direction signals
respectively.
Control signals:
S1
Drive command forward
S2
Drive command reverse
MS2
Multistep 2 frequency
AP
Acceleration command
S11
Slowdown limit forward
S12
Stop limit forward
S21
Slowdown limit reverse
S22
Stop limit reverse
ES
External stop, used for thermal protection of the motor
Switch S4 - 1
Control method
0
EP2
1
MS2
The switch model has one slowdown input DI4. There are two ways to handle the slowdown command and the
selection is made with switch S4-2. Alternatives are shown in the following table. As the slowdown limit switch
contact opens during running, the maximum speed is limited in the running direction.