R&M Materials Handling VARIABLE SPEED CONTROLS ControlMaster NXT Service Manual User Manual
Page 30

R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
30/53
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
Switch S4 - 2
Slowdown mode
Operation
Description
0
Direction memory on
When the power is turned off, the limit switch status is saved. When power is turned
back on and limit switch circuit is opened, driving is allowed with maximum speed in
the opposite direction.
1
Direction memory off
When the limit switch circuit is opened, the maximum speed is limited in both
directions until the limit switch circuit is closed.
WARNING
Do not turn the direction memory on when a limit switch can be activated
without running the equipment, for example, by an anti collision device or a
tandem drive application.