Not for reproduction – Brute 2800 PSI Pressure Washer User Manual

Page 22

Advertising
background image

22

www.brutepower.com

Winter Storage

NOTICE You must protect your unit from freezing
temperatures.

• Failure to do so will permanently damage your pump and render

your unit inoperable.

• Freeze damage is not covered under warranty.

To protect the unit from freezing temperatures:

1. Follow steps 1-4 in the previous section After Each Use.

2. Use pump saver, Model 6039, to treat pump. This

minimizes freeze damage and lubricates pistons and
seals.

3. If pump saver is not available, connect a 3 ft. (92 cm)

section of garden hose to water inlet adapter. Pour
RV-antifreeze (antifreeze without alcohol) into hose.
Pull recoil handle twice. Disconnect 3 ft. (92 cm) hose.

4. Store unit in a clean, dry area.

Long Term Storage

If you do not plan to use the pressure washer for more than
30 days, you must prepare the engine and pump for long
term storage.

Protect Fuel System

Fuel Additive:

Fuel can become stale when stored over 30 days. Stale fuel
causes acid and gum deposits to form in the fuel system or
on essential carburetor parts. To keep fuel fresh, use Briggs
& Stratton® Advanced Formula Fuel Treatment &
Stabilizer
, available wherever Briggs & Stratton genuine
service parts are sold.

For engines equipped with a FRESH START® fuel cap, use
Briggs & Stratton FRESH START® available in a drip
concentrate cartridge.

There is no need to drain gasoline from the engine if a fuel
stabilizer is added according to instructions. Run the engine
for 2 minutes to circulate the stabilizer throughout the fuel
system before storage.

If gasoline in the engine has not been treated with a fuel
stabilizer, it must be drained into an approved container. Run
the engine until it stops from lack of fuel. The use of a fuel
stabilizer in the storage container is recommended to
maintain freshness.

Change Oil

While engine is still warm, drain oil from crankcase. Refill
with recommended grade. See Changing Engine Oil in Engine
Maintenance

.

Protecting the Pump

To protect the pump from damage caused by mineral
deposits or freezing, use PumpSaver, Model 6039, to treat
pump. This prevents freeze damage and lubricates pistons
and seals.

NOTICE You must protect your unit from freezing
temperatures.

• Failure to do so will permanently damage your pump and render

your unit inoperable.

• Freeze damage is not covered under warranty.

NOTICE PumpSaver is available as an optional accessory. It
is not included with the pressure washer. Contact the nearest
authorized service center to purchase PumpSaver.

To use PumpSaver, make sure the pressure washer is turned
off and disconnected from supply water. Read and follow all
instructions and warnings given on the PumpSaver
container.

Other Storage Tips

1. DO NOT store fuel from one season to another unless it

has been treated as described in Protect Fuel System.

2. Replace fuel container if it starts to rust. Rust and/or

dirt in fuel can cause problems if it’s used with this
unit.

3. Cover unit with a suitable protective cover that does not

retain moisture.

4. Store unit in a clean and dry area.

WARNING Storage covers could cause a fire

resulting in death or serious injury.

• DO NOT place a storage cover over a hot pressure washer.

• Let equipment cool for a sufficient time before placing the

cover on the equipment.

Not

for

Reproduction

Advertising