3. Unpacking and assembly
The microscope is packed in a molded styro-
foam container. 
•
Take the container out of the carton remove 
the tape and carefully lift the top half off the 
container. Be careful not to let the optical 
items (objectives and eyepieces) drop down. 
•
To avoid condensation on the optical compo-
nents, leave the microscope in the original pack-
ing to allow it to adjust to room temperature. 
•
Using both hands (one around the pillar and 
one around the base), lift the microscope 
from the container and put it on a stable desk. 
The microscope is fully assembled except for the 
eye-shields. Position them over the eyepieces for 
viewing comfort and to block out any ambient 
light. In addition, the object plate must be inserted 
into the stage opening in the base. Please note 
that you must remove the protective paper. With 
the microscope you will find also a glass object 
plate for transmitted- and mixed-light illumination. 
4. Operation
4.1 General information
•
Set the microscope on a level table.
•
Place the object to be observed in the center 
of the object plate. Use the clips to fasten it 
into place. 
•
Connect the mains cable to the net and turn 
on the switch to get the object illuminated. 
•
When using transmitted- or mixed-light illu-
mination replace black and white plate with 
the glass plate. 
•
Turn the objective to get the desired magnification.
•
On the rotary switch position I is for transmit-
tedlight, position II is for top-light and posi-
tion III is for mixed-light. 
•
Adjust the interpupillary distance between 
the eyepieces by grasping the two prism-
housings with both hands and moving them 
until one circle of light can be seen. 
•
Focus the object by turning the side knobs.
•
It might be necessary to loosen the lock-
screw and raise or lower the entire stereo 
head-bracket until the outline of the object is 
found in the field of view. 
•
Be sure to tighten the lock-screw to fix the 
height of the stereo head on the pillar. 
•
Always turn off the light immediately after use.
•
Be careful not to spill any liquids on the mi-
croscope. 
•
Do not mishandle or impose unnecessary 
force on the microscope. 
•
Do not wipe the optics with your hands.
•
Do not attempt to service the microscope yourself.
4.2 Changing the lamp and fuse
4.2.1 Changing the lamp
•
Turn off the power switch, unplug the mains 
plug and let the lamp cool down. 
•
To change the lamp of the top light loosen 
the lock-screw for the lamp-housing and re-
move the lamp screen. 
•
Remove the lamp and insert a new one.
•
Remount the lamp screen.
•
To change the lamp of bottom light remove 
the cover from the base opening. 
•
Change the lamp in a similar way as de-
scribed above. 
•
Remount the cover.
4.2.2 Changing the fuse
•
Turn off the power switch and unplug the 
mains plug. 
•
Unscrew the fuse holder on the back of the 
stand base with a screwdriver. 
•
Replace the fuse and reinsert the holder in 
its socket. 
5. Storage, cleaning, disposal
•
Keep the microscope in a clean, dry and 
dust free place. 
•
When not in use always cover the micro-
scope with the dust cover. 
•
Do not expose it to temperatures below 0°C 
and above 40°C and a max. relative humid-
ity of over 85%. 
•
Always unplug the mains plug before clean-
ing or maintenance. 
•
Do not clean the unit with volatile solvents or 
abrasive cleaners. 
•
Do not disassemble objective or eyepieces 
to attempt to clean them. 
•
Use a soft linen cloth and some ethanol to 
clean the microscope. 
•
Use a soft lens tissue to clean the optics.
•
The packaging should be disposed of at 
local recycling points. 
•
Should you need to dis-
pose of the equipment it-
self, never throw it away 
in normal domestic 
waste. Local regulations 
for the disposal of electri-
cal equipment will apply.