Product Overview

Features & Benefi ts

Th

e UniFlame® II’s integrated amplifi er eliminates the remote fl ame

amplifi er and incorporates two independent fl ame relays with electronic

self-checking, adjustable ON/OFF thresholds and two 4-20 mA analog

outputs from the detector. Each fl ame relay can be set for either sensor

(one for UV, one for IR or both for UV or both for IR). Independent

settings for each relay allow “locked on” detection for any type of fl ame.

Set-up can be done locally using the attached keypad & VFD display,

via a wireless handheld programmer or with Forney Explorer Software

(FEX). Th

e optional wireless handheld programmer creates an intrinsically

safe wireless set-up when using the infrared transmitter within 5 feet of

the detector, eliminating the need to open the detector in order to make

program changes. FEX Software allows users to monitor, display and

program all detector parameters remotely, i.e. from the control room. Th

e

detector has three factory default fi les provided in various sensitivity levels

that can be used to initiate and test the detector. Th

e auto tune feature

allows the user to learn the “fl ame on” and “background” conditions to

automatically set the detector up.

Connecting to the UniFlame® II is done by multi-pin connectors or

terminal blocks. Th

e standard UniFlame® II has one 8-pin and one 12-

pin electrical cable quick disconnect while the CEX versions use internal

terminal blocks for cable connection.

M

AXIMUM

F

LEXIBILITY

• AutoTune - Fast auto set-up by “learning”

the fl ame and background conditions

• UniFlame® II senses both UV and IR with

independent fl exible discrete outputs

U

NIVERSAL

H

OUSING

• Rugged standard housing is NEMA 4X

(IP66); Class I Div 2 Group A,B,C&D;
Ex nA nC IIC T4

• Alternate housing cap for ATEX, IEC Ex

d IIC T6

• Removable display or remote program-

ming

• Intrinsically safe wireless set-up when

using infrared transmitter to program
within 5 feet of detector

W

ORLDWIDE

A

GENCY

A

PPROVALS

C

UL

US

, FM, ATEX, DIN-DVGW,

DIN-CERTO, CE, AGA, ABS,
INMETRO UL-BR (not all approvals
apply to all models)

UniFlame® II Unitized Flame Detector

Forney’s UniFlame® II series fl ame
detectors utilize micro-processor based
controllers in conjunction with solid
state infrared (IR) and ultraviolet
(UV) sensors and dual cell technology
for optimal fl ame detection and
discrimination.