Changing program data – Dexter Laundry T-50 (On-Premise) User Manual

Page 15

Advertising
background image

- -

15

CHANGING PROGRAM DATA

Put the dryer in PROGRAM mode as instructed on page 13. The dryer remains in the PROGRAM mode until one of

these actions occur:

• The Program Button is actuated again.

• The eighteenth step is completed and the "Start"

button is pushed following the eighteenth step.

• Programming is stopped for about a minute.

• The loading door is closed.

Observe the displayed value in each step. If no change is required, press "Start"

button to advance to the

next program step. If a change is required, the values are made larger by the HIGH button, smaller by the MED

button. The hour meter and the money audit can be reset to zero if the LOW button is pressed.

Note that after any reset or program change, it is necessary to advance to the next step by pressing "Start"

button to enter the revision. OTHERWISE, THE VALUE WILL REMAIN AS IT WAS BEFORE THE ALTERATION.

AVAILABLE OPTIONS

The following two features are available in the dryer. Disconnect power from the machine for two minutes

before modifying the machine for either option.

Anti-Wrinkle Option

The dryer is shipped with this feature defeated. As shipped, when the machine stops at the end of the cycle,

the load will sit motionless in the machine until the user removes the load. The feature is activated by removing

the small jumper indicated in the figure of the PROGRAMMING INSTRUCTIONS. When the feature is activated, it
comes into operation at the end of every cycle if the door is not opened within five minutes after the cycle

finishes. At the end of this five-minute period, the machine will turn on and run for 10 seconds to redistribute the

load. This will occur after each 5-minute interval that goes by without the door ever having been opened for up

to 16 times. The opening of the door any time during this period will prevent any further occurrences for the

particular cycle.

Last Temperature Used Option

There is a jumper on the control for this feature as shown in the figure of the PROGRAMMING INSTRUCTIONS.

As shipped, from the factory, with the jumper in place, this feature is defeated. This means that at the beginning
of each new cycle, the temperature will default to LOW if another temperature isn’t selected by the customer.

If the jumper is removed from the control, the operation is changed, so that when starting a new cycle, the

temperature remains at the last temperature selection used in the previous cycle. This would mean if the
previous customer has used a HIGH selection and the next customer didn’t select anything different, they also
would receive a HIGH cycle.