IQ–P.I.P.–SLM Programmable Input Processor with Load Monitoring for IQ Systems

Reference Manual

AUX

CONNECTOR

GND

+15 V

AUXILIARY

EQUIPMENT

110 VAC

SOLID

STATE

RELAY

(C 8063-3)

+

INPUT

Fig. 4.11 A Sample AUX Output Circuit

channels have failed a test. By reversing the logic, the
AUX output will not send a pass signal when the unit is
turned off or has no power.

4.9.3 Controlling External Devices (AUX Output)
There are many other possible uses for the AUX out-
put. For example, it can be used to turn on auxiliary
cooling fans. To do this the +15 VDC AUX output would
be used to close a relay. The relay would then turn the
fans on or off. This principal is illustrated in Figure 4.11
below:

devices can be synchronized so they function in uni-
son as a group. At least one

IQ–SLM-8 must be active

in the

IQ System in order to configure the system in

Sync mode. Here are the steps for synchronizing mul-
tiple

IQ–P.I.P.–SLMs and IQ–SLM-8s:

1 Select one of the

SLM-8s and use its Generator

Out to insert the test signal upstream of all

IQ–

SLM-8 and IQ–P.I.P.–SLM monitor points in the
audio system.

2 Set the “Generator” and “Sweep” settings of all

SLM P.I.P.s and components so they are all the
same.

3 Turn on the “Sync” control of each unit.

After the above preparations have been made, there
are two ways to generate a synchronized test. The first
way is to use the IQ software’s “All Start” command to
simultaneously initiate a test with all units. Of course,
this requires that all units be connected to an

IQ Sys-

tem. Incidentally, you can stop a test that is in progress
with the “All Abort” command.

The second way to generate a synchronized test is with
the AUX input. This enables you to perform synchro-
nized testing with stand-alone units that are no longer
connected to an

IQ System. To use this method you will

need to turn on the AUX In Trigger setting when the
units are being configured before they are discon-
nected from the

IQ System. Then you will need to con-

nect the AUX inputs of all units to the same trigger
circuit (a +5 to +15 VDC logic circuit as described in
Section 4.7.2). When the AUX inputs sense a logic high,
the units will start a test. To abort a test, simply send a
second logic high.

Note: A Crown part number is provided in Figure 4.11
for a suitable solid-state relay (C 8063-3). Contact your
local Crown representative or the Crown factory Parts
Department (219-294-8200) to order.

4.10 Synchronous Setup

In a large audio system it may be desirable to use the
IQ–P.I.P.–SLM with one or more IQ–SLM-8s and/or IQ–
P.I.P.–SLMs. When this is done, these load-monitoring