SOLO 456 Handbetätigte Druckspritze User Manual

Page 11

Advertising
background image

ENGLISH

3

To pump, loosen the pump handle by turning out
of the stop position. Pump the unit until the
operating pressure is reached in the container.
Excessive pressure escapes automatically through
the safety valve. (4) Take the spray tube in your
hand and start the spray process by pressing the
shut-off valve. Releasing the shut-off valve stops
the spray process.

The shut-off valve can be blocked in the rest
position with the red clamp, to prevent unintended
spraying.

Alternativ spray nozzles see the accessory
overview on the original packaging.

The spray tube can be rotated in the shut-off valve
– after loosening the threaded collar – this is
useful for spraying under leaves.

The pressure sprayer can also be carried by the
pump handle, if the pump handle is pressed down
completely, and it is turned to the right and clicked
into position.

4. Cleaning, care and storage

After each use, release pressure, always keeping
the sprayer in vertical position. Empty the
container, carefully clean, and rinse well with clean
water. Do not empty residual quantities of spray
liquid into watercourses; rather dispose of them via
communal disposal systems.
For cleaning nozzle, spray tube, and shut-off
valve, operate the sprayer using clean water (add
dishwashing detergent if required).


Occasionally clean the filter and spray nozzle with
water and a soft brush. Never use your mouth to
blow through the spray nozzle!

Never use aggressive, acidcontaining, solvent-
containing cleaning substances (gasoline for
example).

Always empty the sprayer completely and store it
in a location that is dry, frost-free, and protected
from direct sunlight.

For proper sealing of tank,
cap gasket (10) must be well
greased with silicone grease.










If the pump is hard to operate, the sealing ring (Fig.
7 – Pos. 11) should be greased with silicone
grease or replaced if necessary. The pump has to
be disassembled as follows for this job:
Fig.4: Ensure the sprayer is empty and not
pressurized. Place sprayer securely on level
ground. When the pump is completely screwed
onto container, loosen pump with 1 – 2 turns.
Fig. 5: Firmly hold the pump handle with both
hands and push downwards until the pump
releases from the flange housing with an audible
click. Unscrew the red flange housing from the
sprayer and remove the pump from the container.
Fig. 6: Use a screwdriver to lever both black flange
semi-circles from the pump cylinder. The pump
piston can now be pulled from the pump cylinder.
Fig. 7: The sealing rig (11) can now be re-greased
with silicone grease or replaced if damaged.

Assembly:
Fig. 8: Place the red flange housing correctly on
the pump piston.

Push the pump piston into the pump cylinder. Push
both black flange semi-circles onto the pump
cylinder until they lock with an audible click.
Fig. 9: Place the pump cylinder securely on level
ground. Line up the red flange housing in the exact
position and firmly push the red flange housing
down with both hands onto the pump cylinder until
the parts lock together with an audible click.

Consult your dealer if you have questions.