SENA ProBee-ZE10 User Manual
Page 75
75
ProBee-ZE10 User Guide Rev.1.5
7.9.3
AT+PARITY or AT+UP
Description
Get/Set the serial parity setting on the module.
Execute
AT+PARITY?<CR>
AT+PARITY=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
0
Range
0 - 2
7.9.4
AT+STOPBIT or AT+US
Description
Get/Set the serial stop bit setting on the module.
Execute
AT+STOPBIT?<CR>
AT+STOPBIT=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
1
Range
1 - 2
7.9.5
AT+FLOWCTRL or AT+UF
Description
Get/Set flow control status. (0: none, 1: software, 2: hardware flow control)
Execute
AT+FLOWCTRL?<CR>
AT+FLOWCTRL=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
0
Range
0 - 2
7.10
GPIO
7.10.1 AT+GPIO or AT+IO
Description
Get/Set the configuration status of GPIO individually or all at once. Only GPIO3-6 can
be set 4, others are available 0-3 and 5.
Execute
AT+GPIO?<CR> or
AT+GPIO<number>?<CR>
AT+GPIO=<values><CR> or
AT+GPIO<number>=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
5550000055550
Range
GPIO3-6: 0-5, the others: 0-3 and 5
0
Disabled (unmonitored digital input)
1
Digital input, monitored
2
Digital output, default low
3
Digital output, default high
4
Analog input, single ended (only valid for GPIO3~6)