background image

4-4

••••

Chapter 4 Configuring an AV-300i Version 2 Drive

GEH-6412 Toolbox for AV-300i Version 2 Drive

Configuring the Drive

For details of the Toolbox
Work Area, see Chapter 3, the
section, Work Area.

The Toolbox Work Area is the main screen of an AV-300i Version 2 drive
configuration. This area is used to configure the drive.

When a new drive is created or an existing file is opened, the Outline View displays
the drive name and two items: Main Menu and Block diagram.

The default device name is AVDV1 (additional
new devices are incremented by one).

To modify the device name, see the next section,
Modifying Drive Properties.

Modifying Drive Properties

Ш

Ш

Ш

Ш To modify the drive

Or click the right mouse
button and select Modify.

1. From the Outline View, click on the drive name.

2. From the Edit menu, select Modify. The Edit Device Properties dialog box

displays.

Select the active communications
network from the drop-down list.

Note ISBus interface and Genius
are contained in this list because
they invoke special toolbox handling.
Other networks, such as Devicenet
and Profibus, do not require
additional handling and are directly
configured in the hardware and
communication/SBI menu.

Gateway IP Address allows you to
enter the IP address or name of the
Innovation Series Controller that is
used as a gateway to the drives via
the ISBus. (This setting is only
enabled if the drive is connected to
the ISBus and used explicitly for
asynchronous toolbox
communications to the drive.)

Enter a note to describe
the drive.

Select the regulation mode in which the
drive wil operate. Typical modes are V/f,
Sensorless, or Field oriented control.

Gateway ISBus Port allows you to select the
Innovation Series Controller physical ISBus port to
which this drive is connected. (This setting is only
enabled if the drive is connected to the ISBus and
used explicitly for asynchronous toolbox
communications to the drive.)

The default device name is AVDV1.
Additional new drives are incremented
by one. You should edit the name to
more accurately reflect the drive being
configured (for example, ROLL1).
This field is limited to five characters.