Chapter 4 Configuring an AV-300i Version 2 Drive

GEH-6412 Toolbox for AV-300i Version 2 Drive

Fault History

Ш

Ш

Ш

Ш To display the Fault History list
w From the View menu, select Fault History. The Fault History List dialog

box displays.

This list is stored in
the drive.

A list of faults that
have cumulated
since power was
applied to the drive
displays. The

most

recent fault appears
at the top.

Click

to display a

description of the
selected fault.

Self-Tune

For more information, refer
to GEH-6641, AV-300i
Version 2 User's Manual, and
GEI-100429, AV-300i
Version 2 Hardware Manual
and Quick Startup Guide.

Self-tune is a process where the drive and the motor perform predefined tests to
determine the best running conditions for the system. There are two types of
self-tunes that are supported: Current Regulator and Speed Regulator.

Self-tune the Current Regulator

Ø To self-tune the current regulator on a drive

Or click

1. Create or open an AV-300i Version 2 drive (see the section, Creating an

AV-300i Version 2 Drive).

2. From the Device menu, select Online.

3. From the Device menu, select Self-Tune, and then select Current

Regulator.

Before the current Regulator can be tuned, the drive must be restarted in the Setup
mode. Once the drive is in the Setup mode, the Motor and Drive data that is
contained in the toolbox configuration file is sent to the drive.