Absolute maximum ratings, Electrical specifications – GE Industrial Solutions FNW500R Series User Manual

Page 2

Advertising
background image

Data Sheet

October 5, 2009

FNW500R Power Modules; DC-DC Converters

36 – 75 Vdc Input; 28Vdc Output; 500W Output

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage (Continuous)

All

V

IN

-0.3 80 Vdc

Operating Ambient Temperature
Note: When the operating ambient temperature is within
55C~85C, the application of the module refers to the
derating curves of Figure 16.

All Ta

-40 85 °C

Operating Case Temperature
(See Thermal Considerations section)

All Tc -40 100 °C

Storage Temperature

All

T

stg

-55 125 °C

I/O Isolation Voltage ,Input to case

All

1500 Vdc

Output to case

All

500 Vdc

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

36 48

75 Vdc

Maximum Input Current

(V

IN

=36V to 75V, I

O

=I

O, max

) All

I

IN,max

18

Adc

Inrush Transient

All

I

2

t

2

A

2

s

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; V

IN

=0V to

75V, I

O

= I

Omax

; see Figure 10)

All

40

mAp-p

Input Ripple Rejection (120Hz)

All

50

dB

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
an integrated part of complex power architecture. To preserve maximum flexibility, internal fusing is not included.
Always use an input line fuse, to achieve maximum safety and system protection. The safety agencies require a
time-delay or fast-acting fuse with a maximum rating of 30 A (see Safety Considerations section). Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.