GE Industrial Solutions CLP0212 User Manual

Clp0212 open frame power supply, Preliminary data sheet, Features

Advertising
background image

GE

Preliminary Data Sheet

October 11, 2013

©2012 General Electric Corporation. All rights reserved.

CLP0212 Open Frame Power Supply

90 - 264Vac input; 12Vdc output; 200W Output Power

Features

•

Compact size 50.8 mm x 101.6 mm x 36.1 mm

(2 in x 4 in x 1.4 in) with density of 18W/in

3

•

Universal AC Input Range (90 – 264VAC)

•

Output voltage of 12V (adjustable ±5%)

•

Maximum output current of 16.7A@ 12Vout (200W)

•

Standby output of 5V or 3.3V @ 0.25A

•

High efficiency with 80 PLUS® Gold Certification

•

Full load capability at 50ºC and 1m/s (200LFM) airflow

with derating at higher temperatures or lower airflows

•

Remote ON/OFF

•

Output overcurrent protection (non-latching)

•

Overtemperature protection

•

Output overvoltage protection

•

Up to 12ms of holdup time

•

Parallellable with current sharing

•

Active power factor corrected input

•

Conducted EMI - meets CISPR22 (EN55022) and FCC

Class A requirements

•

Compliant to RoHS EU Directive 2002/95/EC

•

UL and cUL approved to UL/CSA60950-1, TUV

(EN60950-1), CE Mark (for LVD) and CB Report available

•

ISO** 9001 and ISO 14001 certified manufacturing

facilities

Applications

•

Telecommunications equipment

•

Embedded Computing

•

Storage Systems

•

Industrial equipment

Description

In a small 2 x 4 inch footprint, the 12Vdc single-output CLP0212 open frame power supply delivers 80 PLUS Gold energy

efficiency. With its small siz e, t he CLP series is specifically designed to handle power challenges associated with tight

space and low airflow. Offering a leading 18W/in

3

power density in a 1U high, fan- less form factor, the CLP series addresses a

broad range of applications in new products from communications, computing and data storage original equipment

manufacturers (OEMs). It delivers greater than 90 percent typical power efficiency and full load output at +50˚C (122˚F) with

higher temperature operation possible at derated output. The CLP series utilizes a unique design approach at this power level,

leveraging zero voltage switching techniques in conjunction with quasi-resonant power factor correction (PFC) circuits.

Protection features include overcurrent (OCP), overvoltage (OVP), and overtemperature (OTP).

*

UL is a registered trademark of Underwriters Laboratories, Inc.

†

CSA is a registered trademark of Canadian Standards Association.

‡

VDE is a trademark of Verband Deutscher Elektrotechniker e.V.

** ISO is a registered trademark of the International Organization of Standards

Advertising