Feature specifications (cont.), Environmental specifications, Clp0212 open frame power supply – GE Industrial Solutions CLP0212 User Manual

Page 4: Preliminary data sheet

Advertising
background image

GE

Preliminary Data Sheet

CLP0212 Open Frame Power Supply

90 - 264Vac input; 12Vdc output; 200W Output Power

October 11, 2013

©2012 General Electric Corporation. All rights reserved.

Page 4

Feature Specifications (cont.)

Parameter

Device

Min

Typ

Max

Unit

Input Undervoltage lockout

3

Turn-on Threshold (100% load)

All

86

Vac

Turn-off Threshold (100% load)

All

82

Vac

DC OK – open collector, High when output available

Sink Current

All

4

mA

Maximum Collector Voltage

All

12

V

Environmental Specifications

Parameter

Device

Specification

Conducted Emissions

All

CISPR22 (EN55022) Class A with 3dB margin

Input Harmonics

All

EN61000-3-2

ESD

All

IEC 61000-4-2, Level 3

Radiated Immunity

All

IEC 61000-4-3, Level 2*

Electrical Fast Transient Common Mode

All

IEC 61000-4-4, Level 3

Surge Immunity

All

IEC 61000-4-5, Level 3

Conducted RF Immunity

All

IEC 61000-4-6, Level 3

Voltage Dips

All

EN61000 4.11, Level 3, Class B, C

Shock and Vibration

Operating Shock

All

Three shocks, 15G peak, 11ms sine wave, two axes

Non-Operating Shock

All

Three shocks, 50G peak, 11ms sine wave, two axes

Operating and Non-Operating Vibration

All

5 – 9Hz, 0.5” double amplitude, 2G Peak, 0.5 oct./min., 2 cycles

9-500Hz, 4G pk-pk, 0.5 oct/min., 2 cycles


* Radiated immunity is met when the power supply is tested in a suitable enclosure.

3

The undervoltage lockout thresholds vary with output load current level – decreasing as the load goes down