13

—————— I/O Expansion card ——————

D14A4F

General data

I/O scan time ________________________________ 2ms

Internal power supply from the drive ____________ +5VDC, ±18VDC

N

OTE

!

The Drive TB can be used to supply 24VDC power. AV-300i
24VDC supply maximum output = 120 mA total including
Encoder, LAN, Expansion card and DGF (or 350 mA without
DGF).

Digital inputs

Input type _________________________________ Voltage/Optocoupled

Inputs no. __________________________________ 8 (2 groups of 4 inputs)

0V connection _______________________________ different 0V for the groups

Voltage input value ___________________________ 15 up to 30V

Current input value ___________________________ 4.5 up to 9mA

Digital outputs

Output type ________________________________ open emitter/Optocoupled

Pull down __________________________________ 10 k

Outputs no. ________________________________ 6

External power supply ________________________ 15 up to 30V

Output current ______________________________ 50mA max for any output

Output voltage ______________________________ Power supply less 1V @50mA

Analog inputs

Input type (differential) _______________________ Voltage or Current

Inputs no. __________________________________ 2

Input voltage (con ingresso in tensione) ___________ ±10V

Current requirements (with Voltage ref in input) ____ <0.5mA

Input current (with current ref in input) __________ 0 up to 20mA/4 up to 20mA

Bandwidth _________________________________ 100Hz