GE Industrial Solutions 6KCV300WPD User Manual
Page 147
Win+Drive
o d s
Description
Synchronous communication
It copies the value read by the input ports
vl,
in the synchronous comrnuncation structure
DGFC
shows the result of the operation in the output port
r.The
indexes of the DRIVE param-
eters that are to be updated are specified by Parameters
ipa2, ipa3,
programming
of the
communication structure is performed during
transition.
Input ports
name type
alternative type function
I
Value to be written
slot 0 of the
communication
structure.
v l
float
I Value to be written in
slot 1 of the communication
I
I
structure.
v2
I float I
Value to
be written
slot 2 of the communication
structure.
v3
float
Value to be written in
slot 3 of the communication
I I
I
v4
float
Value
to be written in
slot 4 of the communication
structure.
Output ports
name type
alternative type function
r
Result of the operation: 0 = failed operation
1
= successful operation
137