GE Industrial Solutions 6KCV300WPD User Manual
Page 72
Advertising
GEI-100340
With two digital encoders with a resolution of 1000 counts/rev each and a sample time of 10 msec,
and WMotThr2 should be larger than 10 rpm and 100 rpm respectively.
Minimum diameter
maximum diameter
maximum thickness
inputs
are provided to limit possible error estimations. Zero is minimum thickness.
User can initialize diameter and thickness using Initialize input. When this input is different from zero
diameter (Diameter) and thickness (Thick) are respectively set to
and
62
Advertising